loading

ZXY: 26 Years of Excellence as a Leading Transformer and Inductor Manufacturer ・ One-Stop Solutions

RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 1
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 2
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 3
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 4
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 5
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 6
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 7
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 8
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 9
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 1
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 2
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 3
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 4
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 5
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 6
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 7
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 8
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 9

RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount

800 VA toroidal transformer, 220 V 50 Hz in, dual secondary, 130 degrees C cutoff

An 800 VA toroid for a power amplifier supply. Two separate secondaries on yellow and blue leads give two rectifier feeds from one part, which is what a dual rail needs, and the toroidal core keeps the field close to the winding so the transformer can sit inside the chassis next to the input stage. The centre bolt mounts it straight to the floor plate, with a rubber cushion between the bolt and the top plate to take the buzz out of the chassis.

RY-800VA toroidal transformer on its black base plate, centre bolt and name plate visible
KEY HIGHLIGHTS
  • 800 VA, 220 V 50 Hz primary on red-red leads, two secondaries on yellow-yellow and blue-blue.
  • Secondary printed as 0 V to 38 V on three name plates and 0 V to 36 V on one, plus the spec text.
  • 130 degrees C thermal cutoff built in, marked on the plate and repeated on the panel.
  • Oxygen-free copper radial winding on a seamless grain-oriented silicon steel core.
  • Zinc-plated centre bolt with rubber cushion and steel washer, black base plate with slotted holes.
  • Diameter, height, weight, bolt thread, per-winding current and test voltage are not published.
Read the plates before ordering. The one number that differs across the material is the secondary voltage, 38 V against 36 V, and the difference is large enough to change the rail voltage after rectification. Everything else on the page is transcribed as printed: 800 VA, 220 V 50 Hz, two secondaries, 130 degrees C cutoff.
5.0
Model:
RY-800VA
Thermal:
130 degrees C cutoff
Output 2:
AC 0 V to 36 V, blue leads
Output 1:
AC 0 V to 36 V, yellow leads
Type:
Toroidal audio power transformer
Rated power:
800 VA
Manufacturer:
Shenzhen Zhixiangyuan Electronics Co., Ltd.
Input:
AC 220 V, 50 Hz
Mounting:
Centre bolt with rubber cushion
Brand:
ZXY
design customization

    oops...!

    no product data.

    Go to homepage
    Bolt thread
    Not stated
    Outer diameter
    Not stated
    Thermal protection
    130 degrees C cutoff
    Plate reading
    0 V to 38 V on three labels
    Certificate numbers
    Not published
    Dielectric test
    Not stated
    Input leads
    Red-red
    Input voltage
    AC 220 V
    Type
    Toroidal audio power transformer
    Weight
    Not stated
    Rated power
    800 VA
    Output 2
    AC 0 V to 36 V, blue-blue
    Output 1
    AC 0 V to 36 V, yellow-yellow
    Model
    RY-800VA
    Frequency
    50 Hz
    Height
    Not stated
    Insulation
    Transparent high-voltage film
    Mounting
    Centre bolt, rubber cushion, base plate
    Winding
    Oxygen-free copper, radial lay
    Core
    Grain-oriented silicon steel, seamless

    1. Product Name

    RY-800VA is the model on the name plate, and the plate carries the whole identity of the part: primary AC 220 V 50 Hz on red leads, secondary 0 V to 38 V on yellow-yellow and 0 V to 38 V on blue-blue, a 130 degrees C thermal marking and a date stamp. The same plate carries the CCC, CE and WEEE marks and the double square insulation symbol. There is no drawing in the material, so the plate is the datasheet.

    The panels describe the same part three ways: a toroidal transformer in a range from 50 VA to 1000 VA, an audio grade transformer, and an 800 VA custom build. They are one product line seen from three angles. The part itself is a mains transformer, not an output transformer: the second aries feed rectifiers and reservoir capacitors, and the audio signal never passes through it.

    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 10
    Specification panel: model, input, both outputs and the 130 degrees C cutoff

    2. What It Does

    A toroid is chosen for two reasons in audio equipment. The core is a continuous ring, so the magnetic path has no gap and the field it throws outside the part is small compared with an EI stack of the same rating; that is what allows it to be bolted inside a chassis near the signal stage. And the winding covers the whole core, so for the same rating the part is lower and wider than a stacked lamination, which suits a slim case. Two separate secondaries on two colours give two isolated feeds, so a dual rail can be built with two bridges and one transformer.

    Two things follow for the chassis design. The bolt is the mounting, so the floor plate needs one hole at the centre and the four slotted holes in the base plate are for the anti-rotation screws, not for the load. And a toroid has a high inrush current at switch-on, so the mains switch and the fuse have to be chosen for that rather than for the 800 VA figure alone.
    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 11
    In a power amplifier: the RY-800VA transformer on the chassis floor beside the reservoir capacitors

    3. Construction and Winding

    The build is visible in the close-ups. A seamless grain-oriented silicon steel core is wound with oxygen-free copper in a radial lay, so the turns stand on edge around the ring rather than being layered flat, which is what keeps the winding short and the resistance low. Paper and film insulation separate the windings, the leads are brought out as flying tails, and the whole toroid is wrapped in a transparent high-voltage insulation film that is visible in the close-up as a glossy skin over the copper.

    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 12
    Supplier panel: oxygen-free copper radial winding on a grain-oriented silicon steel core
    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 13
    Winding close-up: copper radial winding under the transparent high-voltage insulation wrap

    4. Centre Bolt Mounting

    Mounting is a single centre bolt. A black steel top plate is pressed over the toroid, a zinc-plated bolt passes through it and through the core, and a nut with a rubber cushion and a steel washer clamps the assembly down. The rubber is there to break the metal path between the bolt and the plate, which is what keeps chassis vibration out of the core and the core out of the chassis. The toroid stands on a black base plate with four slotted holes at the corners for fixing screws, and the plate is shaped so the part can be turned to bring the leads where they are needed.

    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 14
    Bolt close-up: zinc-plated centre bolt and nut over the vibration-damping cushion and washer
    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 15
    Supplier panel: heavy-duty centre bolt mounting with the rubber cushion callout

    5. Electrical Specifications

    The specification panel gives five lines and the name plate repeats them. Model RY-800VA, 800 VA. Input AC 220 V 50 Hz on red-red. Output 1, AC 0 V to 36 V on yellow-yellow. Output 2, AC 0 V to 36 V on blue-blue. Thermal protection, a 130 degrees C cutoff. The plate on the unit itself reads 0 V to 38 V for both secondaries on three of the photographs and 0 V to 36 V on one, which is the one figure in the material that does not agree with itself.

    5.1 The published set

    ParameterValueNote
    ModelRY-800VAOn the name plate and the panel
    Rated power800 VAThe only power figure given
    InputAC 220 V, 50 HzRed-red leads
    Output 1AC 0 V to 36 VYellow-yellow, per the specification panel
    Output 2AC 0 V to 36 VBlue-blue, per the specification panel
    Output on the plateAC 0 V to 38 VThree labels read 38 V, one reads 36 V
    Thermal protection130 degrees C cutoffMarked on the plate and stated on the panel
    Current per secondaryNot statedSee the note on the derived figure
    The 38 V and 36 V difference is not cosmetic. A secondary is rectified and smoothed, and the DC rail lands at roughly 1.4 times the AC figure, so the two readings put the rail a few volts apart and change what the amplifier can deliver before clipping. Neither the current per secondary nor the regulation is stated, so the usable rail under load cannot be worked out from the page either. Ask for the winding schedule or measure a sample under load before the supply is designed around it.

    6. Measured on the Bench

    One photograph shows the part on a power analyzer with its primary connected: 229.7 V rms, 0.151 A rms, 34.70 W, power factor 0.996, with an oscilloscope trace of the primary voltage and current behind it. The mains in that room was above the 220 V rating and 34.70 W is about 4 percent of the 800 VA rating, so this is a light-load reading rather than a full-load test. It shows the part drawing a sane current with the current trace clean and in phase; it does not give an efficiency, a regulation or a temperature rise.

    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 16
    Bench check: power analyzer reading 229.7 V, 0.151 A, 34.70 W at a power factor of 0.996
    Read the reading as evidence that the part works, not as a datasheet line. No load is described, no secondary is connected in the frame, and a power factor close to one at 4 percent of rating is not what an unloaded transformer looks like. If no-load current, efficiency or regulation matters for the design, ask for all three at a stated load and a stated mains voltage.

    7. Audio Performance and the Range

    The audio claims on the panels are qualitative: ultra-low magnetic stray field, low mechanical hum, high current capability and fast dynamic response. None of them is given a number or a test condition, and the panel that carries them shows a 50 W 24 V unit of the same range rather than the 800 VA part, so they describe the construction and the range rather than this rating. The range itself is published as 50 VA to 1000 VA with single and dual output and OEM or ODM builds, and two of the group labels read EEEIO-C50VA and EEEIO-C100VA, which is a different prefix from RY-800VA.

    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 17
    Supplier panel: hi-fi audio grade claims, shown on a 50 W 24 V unit of the same range
    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 18
    Supplier panel: the toroidal range from 50 VA to 1000 VA, single and dual output
    Treat the audio claims as design intent, not as measurements. Stray field, hum and dynamic response are all things a buyer can ask to have measured on a sample, and none of them is quantified here. The group photograph is a family shot and its labels belong to other ratings, so it does not certify anything about the 800 VA build.

    8. Packaging and Delivery

    Supply format is a carton with a moulded EPE foam insert, described as a drop-tested heavy duty carton. The photograph shows six units standing in the foam in one box, which is how the range is shipped rather than a statement about the quantity per carton for this rating. No quantity, carton size or weight is given.

    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 19
    Supplier panel: export packaging, moulded EPE foam insert in a heavy carton

    9. Quality and Compliance

    The compliance panel shows four marks, CCC, CE, RoHS and UL, under a heading about international quality certifications and standards, with a line across the top that presents all four as covering the part. The name plate itself carries CCC, CE, the double square insulation symbol, a damp-proof umbrella and the WEEE bin. No certificate number, standards reference or report is reproduced with any of them, and the UL mark is shown without the Recognized wording that a component approval normally carries.

    RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 20
    Compliance panel: CCC, CE, RoHS and UL marks, with the name plate readable on the unit
    ItemStatementNote
    Thermal cutoff130 degrees CStated on the plate and the panel
    Dielectric testNot statedNo test voltage published
    Insulation resistanceNot statedNot published
    CCCMark shownNo certificate number
    CEMark shownNo certificate number
    RoHS and ULMarks shownNo certificate number, UL not marked Recognized

    10. Feature

    800 VA in a toroid. Two secondaries on one core, wound to the rating, with the low profile a toroid gives for the same power.

    Two isolated secondaries. Yellow-yellow and blue-blue, each 0 V to 36 V or 38 V depending on the plate, so a dual rail comes from one part.

    130 degrees C cutoff. A thermal element inside the winding, marked on the plate and stated on the specification panel as the protection.

    Oxygen-free copper, radial lay. The winding stands on edge around the core, which keeps the turns short and the resistance low.

    Grain-oriented core. A seamless silicon steel ring with no gap in the magnetic path, which is what keeps the stray field down.

    Centre bolt with rubber cushion. One bolt through the core clamps the part to the chassis, with a rubber cushion and steel washer between bolt and top plate.

    11. Advantage

    It fits inside the chassis. A toroid of this rating is low and wide, and the small stray field means it can sit near the input stage without inducing hum.

    One part, two rails. Two isolated secondaries remove the second transformer a dual rail supply would otherwise need.

    The bolt is the mount. One hole in the floor plate and four anti-rotation screws, instead of a cradle or a bracket.

    The rubber cushion is the quiet. Breaking the metal path between bolt and plate keeps core vibration out of the chassis.

    A published rating range. The same construction is offered from 50 VA to 1000 VA, so a different rail is a winding change rather than a new design.

    12. Specifications

    Values are transcribed from the supplier panels and the name plates. Where a figure is absent the cell reads Not stated. Where two plates disagree both readings are kept and the conflict is named in the note column rather than resolved here.

    ItemSpecificationNote
    ProductToroidal audio power transformerMains transformer, not an output transformer
    ModelRY-800VAPrinted on the name plate
    Rated power800 VAWinding rating, not a delivered DC figure
    InputAC 220 V, 50 HzRed-red leads
    Output 1AC 0 V to 36 V or 38 VYellow-yellow, plates disagree
    Output 2AC 0 V to 36 V or 38 VBlue-blue, plates disagree
    CoreGrain-oriented silicon steel, seamlessGrade not stated
    WindingOxygen-free copper, radial layWire gauge not stated
    InsulationTransparent high-voltage film wrapClass not stated
    Thermal130 degrees C cutoffThe only protection stated
    DimensionsNot statedNo drawing and no dimension callout

    13. Application

    The uses below are the ones the material points at, with a note on why a toroid of this rating fits each. They describe where the part is sold, not a qualification of any one build.

    Power amplifier supplies. The part in the photograph sits on an amplifier floor plate feeding the reservoir bank.

    Preamplifiers and DAC supplies. Where the stray field and the mechanical hum matter more than the rating.

    Active loudspeakers. One transformer inside the cabinet, with the rectifiers and capacitors on the amplifier board.

    Studio and instrument amplifiers. A dual rail from two secondaries, with the 130 degrees C cutoff as the thermal backstop.

    Industrial and control panels. Where a low profile and a bolted mount suit a crowded enclosure.

    OEM builds across the range. The same construction from 50 VA to 1000 VA, single or dual output, built to order.

    14. Ordering

    Send the rail you need first, then the numbers. A usable enquiry states the mains voltage and frequency, the secondary voltage and the current each winding has to carry, whether the two windings are used as separate rails or in series, the ambient and the mounting position. Ask which secondary voltage the price refers to, 36 V or 38 V, and ask for the diameter, the height, the weight, the bolt thread, the base plate hole size, the current per winding, the regulation and the test voltage, because none of those is published. If the build is close to this one, quote RY-800VA as the starting point and list the differences.

    On compliance: the panel shows CCC, CE, RoHS and UL and presents all four as covering the part. No certificate number, standards reference or report is reproduced with any of the marks, and the UL mark appears without the Recognized wording. They are reported here as marks and declarations, not as verified approvals. A mains transformer is a safety critical part, so ask for the certificate and the report for the standard your product has to meet before the design is fixed.

    Scope of this page. The model RY-800VA, the 800 VA rating, the 220 V 50 Hz primary on red-red leads, the two secondaries on yellow-yellow and blue-blue leads, the 36 V and 38 V plate readings, the 130 degrees C cutoff, the oxygen-free copper radial winding, the grain-oriented core, the transparent insulation wrap, the centre bolt with rubber cushion, the base plate, the 50 VA to 1000 VA range, the packaging description, the four certification marks and the analyzer readings of 229.7 V, 0.151 A, 34.70 W and 0.996 power factor are transcribed from the twelve supplier panels. The diameter, height, weight, bolt thread, hole size, current per winding, regulation, efficiency, no-load current, temperature rise, insulation class, dielectric test voltage, lead length and certificate numbers are absent from the source and are left open rather than estimated. The 4 percent figure is arithmetic on the published rating and the bench reading, and is marked as such. All twelve supplied images are used on the page, ten in the gallery and two inline.

    Brand / manufacturer: ZXY, Shenzhen Zhixiangyuan Electronics Co., Ltd. http://www.zxycoil.com

    Message Form
    We Can Help You Solve Any Problem 
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    Huizhou Company Address
    Zhixiangyuan Technology Co., Ltd., 5th Floor, Building 4, Xinghe Industrial Park, Zhongkai High tech Zone, Huicheng District, Huizhou City, Guangdong Province
    Contact Us
    Contact Person: Rhea Chen
    Tel/WhatsApp: +86 13554723725
    Fax: 86-0755-23779620
    Shenzhen Company Address
    Room 202, Yingfei Haocheng Science and Technology Park, Guansheng 5th Road, Luhu Community, Guanhu Street, Longhua District, Shenzhen City, Guangdong Province, China
    Customer service
    detect