loading

ZXY: 26 Years of Excellence as a Leading Transformer and Inductor Manufacturer ・ One-Stop Solutions

ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 1
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 2
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 3
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 4
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 5
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 6
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 7
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 8
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 9
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 10
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 1
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 2
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 3
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 4
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 5
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 6
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 7
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 8
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 9
ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD 10

ZXY-ED8 Permalloy Audio Isolation Transformer — 600:600 & 10K:600, 0.1-5 W, 2.0 kV AC, Shielded SMD

Shielded permalloy audio transformer, 600 Ω and 10 kΩ lines, 0.1-5 W, SMD

ZXY-ED8 is a miniature shielded permalloy audio isolation transformer for 0.1 W to 5 W audio and communication circuits. Two standard ratios, 600:600 and 10K:600, cover the usual matching jobs; a permalloy core and a metal shielding shell do the magnetic and the EMI work in the same small can, and the part is designed to go onto the board through a standard SMT line.

ZXY-ED8, labelled ED8 Permalloy Audio Transformer, 600:600 and 10K:600
ZXY-ED8, labelled ED8 Permalloy Audio Transformer, 600:600 and 10K:600
KEY HIGHLIGHTS
  • Permalloy core with efficiency of 92 % or higher, stated for the series
  • Metal shielding shell: dustproof, moisture-proof, anti-EMI/RFI
  • Standard 600:600 and 10K:600 impedance ratios, custom ratios to order
  • V-0 flame-retardant bobbin, 130 °C insulation rating
  • 2.0 kV AC withstand voltage for 1 minute, complete galvanic separation
  • Insulation resistance 100 MΩ or more at 500 VDC
  • Compact SMD pad footprint, compatible with automatic SMT assembly
What this page does not state: outline dimensions, pin count, pin pitch, land pattern, weight and operating temperature range are not declared in the source description, so the cells for those fields are left empty rather than estimated. The four-leg SMD outline in the photographs is not a drawing, so confirm the land pattern against the ZXY drawing before layout. No certificate number is quoted because the supplied scans do not name ZXY-ED8 on its own.
5.0
Insulation grade:
V-0, 130 °C
Insulation resistance:
100 MΩ minimum at 500 VDC
Withstand voltage:
2.0 kV AC for 1 minute
Power range:
0.1 W to 5 W
Impedance ratio:
600
OEM / ODM:
Available to drawing or sample
Core material:
Permalloy
Model number:
ZXY-ED8
Brand name:
ZXY
Place of origin:
Guangdong, China
design customization

    oops...!

    no product data.

    Go to homepage
    Outline dimensions
    Not declared, request the drawing
    Manufacturer
    ZXY, Shenzhen Zhixiangyuan Electronics
    Custom ratio
    Available to customer requirement
    Application system
    600 Ω and 10 kΩ lines
    Service life
    Long, without signal distortion
    Temperature performance
    Low rise under full load
    Efficiency
    92 % or higher
    Galvanic separation
    Complete, between windings
    Withstand voltage
    2.0 kV AC, 1 minute
    Insulation grade
    V-0 flame-retardant, 130 °C
    Impedance ratio
    600
    Power range
    0.1 W to 5 W
    Insulation resistance
    100 MΩ minimum at 500 VDC
    Core material
    Permalloy, laminated
    Product type
    Shielded permalloy audio isolation transformer
    Assembly
    Compatible with automatic SMT
    Model
    ZXY-ED8
    Shielding
    Miniature metal shell, anti-EMI/RFI
    Mounting
    SMD surface mount
    Application
    Audio line isolation and impedance matching

    1. Product Name

    ZXY-ED8, a miniature shielded permalloy audio isolation transformer in a surface-mount package, for low-power audio and communication circuits from 0.1 W to 5 W. Two standard impedance ratios are supplied, 600:600 and 10K:600, and custom ratios are wound to order. The core is permalloy, the housing is a miniature metal shielding shell, and the bobbin is a V-0 flame-retardant moulding rated for 130 °C insulation.

    Three views as labelled on the sheet: back, front and perspective
    Three views as labelled on the sheet: back, front and perspective

    One series, two jobs. The 600:600 build is the line-level matching part, for 600 Ω circuits that need the two sides separated. The 10K:600 build is the step-down ratio, for a high-impedance source feeding a 600 Ω line. Both are the same outline and the same footprint, so a board can be laid out once and populated with either ratio.

    2. Construction & Materials

    The shielding shell. A miniature metal shell around the winding does two jobs that the description separates: it closes the magnetic path against outside fields, and it keeps dust and moisture off the copper. On a crowded board the second job matters as much as the first, because an unshielded audio transformer is an aerial as well as a component.

    Two units side by side: the wound bobbin on the left, the shielded face on the right
    Two units side by side: the wound bobbin on the left, the shielded face on the right

    The core. Permalloy rather than ferrite, which is what lets the part be both small and low-loss at audio frequencies: efficiency is stated as 92 % or higher for the series. The photographs show a laminated permalloy core with the winding laid in the window and a moulded bobbin around it.

    Permalloy core, stated at 92 % efficiency or higher for the series
    Permalloy core, stated at 92 % efficiency or higher for the series

    The insulation. The bobbin is a V-0 flame-retardant moulding with a 130 °C high-temperature-resistant insulation rating, which is what allows the part to be reflowed rather than hand-soldered. Between windings the part withstands 2.0 kV AC for one minute with complete galvanic separation, and insulation resistance is 100 MΩ or more at 500 VDC.

    Called out on the part: permalloy core, precision winding, V-0 flame-retardant bobbin
    Called out on the part: permalloy core, precision winding, V-0 flame-retardant bobbin

    The termination. Solder legs formed for surface mounting at each end of the body, on a pad pattern small enough for the part to sit inside a portable audio board beside the connectors it serves. The description states compatibility with automatic SMT assembly; it does not state the pad geometry, so take that from the drawing.

    Called out on the part: SMD solder pin, 2.0 kV isolation barrier and wire routing slot
    Called out on the part: SMD solder pin, 2.0 kV isolation barrier and wire routing slot

    3. Feature

    Premium permalloy core. Low loss and efficiency of 92 % or higher, for high-fidelity audio signal transmission.

    Miniature metal shielding shell. Dustproof, moisture-proof and anti-EMI/RFI in one part, so the transformer does not have to be boxed separately on the board.

    Low power range, 0.1 W to 5 W. Customizable, sized for mini portable audio and communication devices rather than for line amplifiers.

    Standard 600:600 and 10K:600 ratios. Customizable for various audio circuits; the two standard builds cover line matching and step-down matching.

    V-0 flame-retardant bobbin. 130 °C high-temperature-resistant insulation, which is what makes the part reflow-compatible.

    2.0 kV AC withstand voltage for 1 minute. Complete galvanic circuit separation between windings.

    Insulation resistance 100 MΩ or more at 500 VDC. Tiny leakage current, for clear and stable sound rather than for hum-free-by-luck.

    Low temperature rise under full load. Long service life without signal distortion at the rated power.

    Compact SMD surface-mount pad. Fully compatible with automatic SMT PCB assembly.

    4. Advantage

    Magnetic and shielding work in one package. High permeability and low loss plus EMI/RFI suppression, in a footprint small enough for a portable device.

    Verifiable galvanic separation. 2.0 kV AC withstand voltage and 100 MΩ or more insulation resistance are stated acceptance items, not adjectives.

    Design-in time cut by the standard ratios. 600:600 and 10K:600 are the standard builds; anything else is a custom impedance, wound to order.

    Built for reflow. V-0 and 130 °C-rated materials support SMT production, so the part does not force a hand-solder step into the line.

    Stable under load. Low temperature rise keeps distortion low and service life long at the rated power.

    Custom builds to drawing or sample. OEM permalloy transformer work, from a sample or from a drawing, with the specification confirmed before the run.

    5. Application

    Miniature portable audio and communication equipment. The 0.1 W to 5 W range is where the part is rated: handheld audio, intercoms and small communication devices.

    Audio line isolation and impedance matching. 600 Ω and 10 kΩ systems, which is what the two standard ratios are for.

    EMI/RFI-sensitive boards. Where a shielded audio isolation transformer is the requirement rather than an option.

    SMT production lines. A surface-mount magnetic component that goes through the same reflow as the rest of the board.

    A single unit standing on a plain surface
    A single unit standing on a plain surface
    The part placed on a signal board beside RCA connectors, as an audio line isolation stage
    The part placed on a signal board beside RCA connectors, as an audio line isolation stage

    6. Specifications

    The tables below reproduce the specification as declared for the ED8 series. Where the source gives no figure, the cell says so instead of carrying a number forward from another series.

    6.1 Summary

    ParameterSpecificationNote
    Core materialPremium permalloy core, low lossEfficiency 92 % or higher
    ShieldingMiniature metal shielding shellDustproof, moisture-proof, anti-EMI/RFI
    Power range0.1 W to 5 WCustomizable
    Impedance ratio600:600 and 10K:600 standardCustom ratios available
    Insulation gradeV-0 flame-retardant bobbin130 °C insulation rating
    Withstand voltage2.0 kV AC for 1 minuteComplete galvanic separation
    Insulation resistance100 MΩ or more at 500 VDCNo tolerance declared
    TemperatureLow rise under full loadNo figure declared
    MountingSMD surface-mount padAutomatic SMT compatible

    6.2 Electrical

    ParameterSpecificationTest condition
    Withstand voltage, winding to winding2.0 kV ACApplied for 1 minute
    Galvanic separationCompleteBetween windings
    Insulation resistance100 MΩ minimumMeasured at 500 VDC
    Efficiency92 % or higherSeries claim; test conditions not declared
    Rated power0.1 W to 5 WCustomizable
    Impedance ratio600:600 / 10K:600Standard builds; custom on request
    Isolation stated at 2.0 kV AC and 100 MΩ or more at 500 VDC
    Isolation stated at 2.0 kV AC and 100 MΩ or more at 500 VDC
    Read the dielectric figures with the test conditions the source does not give: 2.0 kV AC for one minute is stated as the withstand voltage between windings, but the document does not say whether the shell is tied to a winding during the test, nor does it give a leakage-current limit or a ramp. The insulation resistance figure is quoted at 500 VDC with no tolerance. Efficiency is a series claim of 92 % or higher, with the measurement frequency, level and load left open, so treat it as a design target rather than a per-unit acceptance limit.

    6.3 Materials and construction

    ItemSpecificationDeclared property
    CorePermalloy, laminatedLow loss, high permeability
    Shielding shellMetalDustproof, moisture-proof, anti-EMI/RFI
    BobbinV-0 flame-retardant moulding130 °C insulation rating
    TerminationSMD solder legsFormed for surface mounting

    6.4 Mechanical and mounting

    ItemValueNote
    MountingSurface mount (SMD)Solder legs at each end of the body
    AssemblyAutomatic SMTStated compatible
    Outline dimensionsNot declaredRequest the drawing before layout
    Pin count and pitchNot declaredRequest the drawing before layout
    Land patternNot declaredRequest the drawing before layout
    WeightNot declaredRequest the drawing
    No outline, no pin-out. The description declares no body dimensions, no pin count, no pin pitch, no land pattern, no weight and no operating temperature range. The photographs show a four-leg surface-mount part on a laminated permalloy core, but a photograph is not a drawing: request the outline and pad drawing before layout, and do not derive a footprint from the images.

    6.5 Quality and testing

    ItemRequirementCondition
    Withstand voltage2.0 kV AC1 minute, between windings
    Insulation resistance100 MΩ or more500 VDC
    Galvanic separationCompleteStated acceptance item
    Efficiency92 % or higherStated acceptance item for the series
    Temperature riseLow under full loadNo figure declared
    Service lifeLong, without signal distortionNo figure declared

    7. Ordering

    The part is ordered as ZXY-ED8 with the impedance ratio stated, 600:600 or 10K:600. The core, the shielding shell, the bobbin and the SMD termination are common to the series; the turns and the copper are set by the ratio, so an order that does not name the ratio cannot be checked against a single acceptance table. Custom permalloy transformer and OEM builds are made to customer drawing or sample.

    Certification: the scans supplied with this description cover the company's quality management system and other ZXY models; none of them names ZXY-ED8 on its own, so no compliance claim is made here and the badge artwork from one of the supplied renders was not used. If the listing needs a certificate, quote the number from the certificate itself.

    Empty cells on purpose: product category, minimum order quantity, stock, weight, dimensions, sales price and cost price are not given in the source description, so they are left blank rather than estimated. Minimum order quantity, packing and lead time are not stated either; both are confirmed on enquiry, as are custom ratios and custom power ratings built to drawing or sample.

    Brand / manufacturer: ZXY, Shenzhen Zhixiangyuan Electronics Co., Ltd. http://www.zxycoil.com

    Message Form
    We Can Help You Solve Any Problem 
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    Huizhou Company Address
    Zhixiangyuan Technology Co., Ltd., 5th Floor, Building 4, Xinghe Industrial Park, Zhongkai High tech Zone, Huicheng District, Huizhou City, Guangdong Province
    Contact Us
    Contact Person: Rhea Chen
    Tel/WhatsApp: +86 13554723725
    Fax: 86-0755-23779620
    Shenzhen Company Address
    Room 202, Yingfei Haocheng Science and Technology Park, Guansheng 5th Road, Luhu Community, Guanhu Street, Longhua District, Shenzhen City, Guangdong Province, China
    Customer service
    detect